| Motor Conversion Table - High Efficiency Motors |
| The current ratings shown in the following table are based on assumed motor efficiencies as indicated. If you know the actual motor efficiency, you can calculate accurate current. See our Electrical Formula page for more information. |
|
| kW | HP | Power Factor (assumed) |
Efficiency (assumed) |
Amps (3 phase 415V) |
Amps (3 phase 445V) |
Amps (1 phase 240V) |
| 0.09 | 1/8 | 0.8 | 0.70 | 0.2 | 0.2 | 0.5 |
| 0.12 | 1/6 | 0.8 | 0.70 | 0.3 | 0.3 | 0.7 |
| 0.18 | 1/4 | 0.8 | 0.70 | 0.4 | 0.4 | 1.1 |
| 0.25 | 1/3 | 0.8 | 0.70 | 0.6 | 0.6 | 1.5 |
| 0.37 | 1/2 | 0.8 | 0.70 | 0.9 | 0.9 | 2.2 |
| 0.55 | 3/4 | 0.8 | 0.75 | 1.3 | 1.2 | 3.1 |
| 0.75 | 1 | 0.8 | 0.75 | 1.7 | 1.6 | 4.2 |
| 1.1 | 1.5 | 0.8 | 0.75 | 2.6 | 2.4 | 6.1 |
| 1.5 | 2 | 0.8 | 0.75 | 3.5 | 3.3 | 8.3 |
| 2.2 | 3 | 0.8 | 0.80 | 4.8 | 4.5 | 11.5 |
| 3.7 | 5 | 0.8 | 0.80 | 8.0 | 7.6 | 19.3 |
| 4 | 5.5 | 0.8 | 0.80 | 8.7 | 8.2 | |
| 5.5 | 7.5 | 0.8 | 0.85 | 11.3 | 10.6 | |
| 7.5 | 10 | 0.8 | 0.85 | 15.3 | 14.5 | |
| 11 | 15 | 0.8 | 0.85 | 22.5 | 21.2 | |
| 15 | 20 | 0.8 | 0.85 | 30.7 | 28.9 | |
| 18.5 | 25 | 0.8 | 0.85 | 37.9 | 35.7 | |
| 22 | 30 | 0.8 | 0.90 | 42.5 | 40.1 | |
| 30 | 40 | 0.8 | 0.90 | 58.0 | 54.7 | |
| 37 | 50 | 0.8 | 0.90 | 80.4 | 75.9 | |
| 45 | 60 | 0.8 | 0.90 | 87.0 | 82.0 | |
| 55 | 75 | 0.8 | 0.90 | 106 | 100 | |
| 75 | 100 | 0.8 | 0.90 | 145 | 137 | |
| 90 | 120 | 0.8 | 0.95 | 165 | 155 | |
| 110 | 150 | 0.8 | 0.95 | 201 | 190 | |
| 150 | 200 | 0.8 | 0.95 | 275 | 259 | |
| 185 | 250 | 0.8 | 0.95 | 339 | 319 | |
| 220 | 300 | 0.8 | 0.95 | 403 | 380 |